Python 240-8XX 091-0593 User Manual

Page 13

Advertising
background image

Millermatic Python

®

Owner's Manual - Page 1

Section A

Installation

Technical Specifications

Wire Capacity
Aluminum and Cored Wire ...........................

.030" - 1/16" (0.8 mm - 1.6 mm)

Solid and Hard Wire .....................................

.030" - .045" (0.6 mm - 1.2 mm)

Wire Speed (At rated feeder input voltage) .............70 - 875 ipm (22.2 mpm)

Duty Cycle - 60% (All ratings are using Argon gas) .............. 225 Amps Peak

Shipping Weight (approximate) ...................................... 19.29 lbs. (8.29 Kg)

Gun weight (less leads) ....................................................... 2.5 lbs. (1.13 Kg)

Support Equipment Required

C.V. or C.C. power source of sufficient capacity for your needs.

Regulated gas supply and hoses.

Properly sized power leads from power source to wire feeder and

ground.

Gun Lead Connections

Power Cable

A #2 AWG power cable is used on the Millermatic Compatible™ Python

®

.

The gun end of the cable has a fitting crimped to the copper cable strands.

This fitting is then threaded into the gun body. The cabinet end of the power

cable is incorporated into the Power Pin connector.
The power cable gun end is a threaded fitting which screws into the gun

body. The cabinet end is secured in the central body with a set screw. These

connections utilize a conductive sealant and are tightened to a specific

torque setting (reference exploded parts drawing in the Appendix for details) .
Conduit

The Millermatic Compatible™ Python

®

comes standard with a poly-lined

conduit, for feeding aluminum wire. The longer fitting with a shallow groove

is used on the gun end. A set screw located on top of the gun handle

secures the conduit in place. The cabinet end of the conduit is secured into

the Power Pin connector with a set screw.
Gas Hose

The gas hose is pushed over barbed fittings on both gun body and the Power

Pin connector and is secured with a plastic tie wrap.
Electric Cable
A multi-conductor control cable is used on the Millermatic Compatible™

Python

®

. The gun end of the cable is secured with a cable clamp and the

wires are connected to the potentiometer, the micro switch, the motor and the

gun body mechanically. Slack is left in the electric cable as it exits the back

of the gun to prevent cable and/or wire breakage. The cabinet end of the

control cable uses a 10-Pin, "X" clocked Amphenol connector.