Filling the Lines the First Time

1. Turn Beer Flow Control Handle OFF.

(See Fig. 1).

2. Tap fresh keg.

3. Turn Beer Flow Control Handle to CLEAN.

(See Fig. 3).

4. Open the beer faucet. When solid beer

appears, close the faucet. The line is full.

5. Turn Beer Flow Control Handle ON.

(See

Fig.2). The line is full and ready for service.

When Tapping Fresh Kegs

1. Remove coupler from empty keg.

2. Turn Beer Flow Control Handle OFF.

(See Fig. 1).

2. Tap fresh keg in normal manner.

3. Turn Beer Flow Control Handle to CLEAN.

position.

(See Fig. 3). Wait for five seconds

then turn to ON position.

(See Fig. 2).

To Restart System

If beer does not flow, first turn the Flow Control
Handle to OFF.

(See Fig. 1). Then turn Handle to

the CLEAN position.

(See Fig. 3). Wait for five

seconds then turn the Handle to ON position.
(See Fig. 2).

To Clean

1. Untap Keg in usual manner.

2. Turn Beer Flow Control Handle OFF.

(See Fig. 1).

3. Attach cleaning adapter. Use Perlick’s

single cleaning adapter, No. 43699, if
cleaning from faucet to keg. If two or
more lines are cleaned, use Perlick’s
dual cleaning adapter, No. 43702.

4. Turn Beer Flow Control Handle to

CLEAN and clean as usual.

(See Fig. 3).

5. After flushing, turn Beer Flow Control

Handle OFF and retap keg.

(See Fig. 1).

6. To restore service, see above instructions.

Warranty

Perlick products are fully guaranteed against defects in both material and
workmanship for a period of one year from date of sale. Defective parts will be
replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We
are not responsible for parts damaged by alteration, unauthorized service,
accident or abuse. All costs incident to replacement to include freight, labor and/or
loss of sales are incidental to this warranty and must be borne by the user.

No. 43699

No. 43702

Single Adapter

Dual Adapter

6

7

5

3

4

10

9

2

1

11

8

Item ........Part No. ....................Description

1. .......40119 .....................Empty keg Sensor
2. .......43090A ..................Std. Yoke Assy.
3. .......2026 .......................Hex Nut
4. .......2068-1....................Tailpiece
5. .......157R2P..................Washer
6. .......23682-2P ...............Check Valve
7. .......31084-1..................Retaining Screw
8. .......31089-2P ...............“O” Ring (3 per assy.)
9. .......43061.....................Body w/relief valve

10. .......31088-2P ...............Bottom Seal Washer

11. .......31479-1..................Probe Washer

Cleaning Adapters

Beer Flow Control

Handle Operating

Positions

Advertising