Partner Tech GBV 345 User Manual

Page 6

Advertising
background image

-- 6 --

3. Hold the vacuum inlet cover open until up-

per vacuum tube is installed.

Vacuum

Inlet

Cover

Vacuum

Inlet

4. Align the tabs on the inside of the vacuum in-

let with the slots on the upper vacuum tube.

Tab

Slot

5. Push the upper vacuum tube into the vac-

uum inlet. Turn the tube counterclockwise

until a click is felt to secure the tube to the

blower unit.

6. Align slanted end of lower vacuum tube as

shown. Push lower vacuum tube into upper

vacuum tube until the lower tube is securely

seated in the upper tube (about 7 cm).

Slanted end of

lower vacuum tube

7. When vacuum tubes are fitted together,

locate the label on the lower portion of the

upper tube. Permanently assemble the two

tubes together with the supplied screw.

Upper

Vacuum

Tube

Lower

Vacuum

Tube

HOW TO CONVERT UNIT FROM

VACUUM USE TO BLOWER USE

1. Remove the elbow tube and vacuum bag

by turning the knob counterclockwise to

loosen the elbow tube.

2. Remove the vacuum tubes by turning the

tubes clockwise.

3. Close the vacuum inlet cover and make

sure it is latched closed.

4. Reinstall the blower tubes (see BLOWER

TUBE ASSEMBLY).

SHOULDER STRAP ADJUSTMENT

1. Hold the unit as shown with the muffler side

facing away from your body and clothes.

2. Pass the shoulder strap over your head

and onto your right shoulder.

3. Extend your left arm toward the rear of the

vacuum bag.

4. Adjust shoulder strap until the vacuum

bag/shoulder strap seam lies between

your thumb and index finger.

5. Make sure air flows freely from the elbow

tube into bag. If bag is kinked, the unit will

not operate properly.

Advertising