Warning – Pentair Light and Return Water Flow Quasar User Manual

Page 8

Advertising
background image

P/N 98748000

8

REV. F

1-6-05

11. Place the junction box cover on the junction box bottom so that the junction box can more easily

snap into the transformer box; see Figure 15. Snap the pieces together, then remove junction box
cover.

12. Mount the transformer box on a pool support approximately 18 inches above the ground, in a

position accessible to electrical connection; see Figure 16. To mount the transformer junction box,
insert one of the screws provided, to a pool support.

NOTE

Do not install the transformer directly onto the pool wall.

13. Pull cord out of the junction box and strip a six (6)

inch section of the outer insulation jacket from the
cord, see Figure 17.

WARNING

Risk of electric shock. Connect only to a circuit

protected by a GFCI. Failure to do so can result in
serious personal injury and/or death.

14. Connect the conduit to the junction box. Make

electrical connections in the junction box. Reinstall
the cover to the junction box.

15. Using the cable clamp provided, attach the cable

clamp to the cord and mount the cable clamp to the
pool support, see Figure 18, so that the cord lies flush
against the pool wall. Do not attach directly to the
pool wall. This will keep the cord flush to the wall;
see Figure 19.

16. Make electrical connections to the power supply

protected by a GFCI. Turn on the power.

17. If the light is not ON, press the switch on the

transformer case once.

Pool
Support

Top
Mounting
Screw

Conduit

Figure 16.

Junction
Box

Conduit

Insulated
Connectors

Figure 17.

Figure 15.

Advertising