Paradyne Dual DSU 7511 User Manual

Page 5

Advertising
background image

5

7511-A2-GN10-10

January 1999

Table 1.

Configuration Options (3 of 5)

Switch

Options and Usage

Default in Bold

64CC Data Scrambler

S1-6 (DSU A)
S3-6 (DSU B)

S1

S2

S3

S4

DSU A

DSU B

ON

ON

ON

ON

Determines whether the DSU scrambles data to minimize the possibility
of the remote DSU falsely recognizing a loopback command.

Off

Disable

Data scrambling is disabled.

ON

Enable

Data scrambling is enabled.

V.54 Sequence
Detection

S1-7 (DSU A)
S3-7 (DSU B)

S1

S2

S3

S4

DSU A

DSU B

ON

ON

ON

ON

Determines whether the DSU responds to V.54 Loop Up and Loop
Down sequences from the remote DSU.

Off

Disable

V.54 loop sequences are ignored.

ON

Enable

The DSU responds to V.54 loop sequences.

Invert
TX Clock

S1-8 (DSU A)
S3-8 (DSU B)

S1

S2

S3

S4

DSU A

DSU B

ON

ON

ON

ON

Determines whether the DSU clock provided on interchange circuit
CT114 (TXC) is phase-inverted with respect to interchange circuit
CT103 (TXD). This can reduce errors encountered due to excessive
cable lengths.

Off

Normal

TXC is not inverted.

ON

Invert

TXC is inverted with respect to TXD.