Add/Remove Data
Refer to “Add/Remove Data” on page 142 for details.

5.13.2.6 EAN 13

Enabled
Set this parameter to on to enable “EAN 13”.

Add/Remove Data
Refer to “Add/Remove Data” on page 142 for details.

5.13.2.7 EAN 8

Enabled
Set this parameter to on to enable “EAN 8”.

EAN-8 Zero Extend
When this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols,
making them compatible in format to EAN-13 symbols. Disabling this parameter returns
EAN-8 symbols to their normal format.

Add/Remove Data
Refer to “Add/Remove Data” on page 142 for details.

5.13.2.8 UPC A

Enabled
Set this parameter to on to enable “UPC A”.

UPC-A, Check Digit
If you enable this parameter, the check digit is included with the decoded bar code data.

UPC-A, Preamble
When you double-tap on this parameter, a dialog box is displayed where you can choose one
of three options for lead-in characters for UPC-A symbols transmitted to the host device:
System Char—system character transmitted with the data,
Country Code and System Char—both the country code (“0” for USA) and system character
are transmitted with the data, or
None—no preamble is transmitted. The lead-in characters are considered part of the symbol.