You will see the following message:

Obtaining IP Addresses for SysMgr/AcctMgr
Failover Operation

Note: If you don't have plan to configure the failover service,
type in the same primary service logical IP address and
primary machine logical IP address or type 0.0.0.0 instead.

17

Enter the <Machine Logical IP Address of the other
MgmtSvr> (in dot-notation format).

Example: 120.120.13.22

18

Enter the <service logical IP address of the
SysMgr> (in dot-notation format).

Example: 120.120.13.22

19

Enter the <service logical IP of the AcctMgr> (in
dot-notation format).
Example: 120.120.13.22

”You have entered the following IP addresses:
Machine Logical IP Address of the other MgmtSvr:
120.120.13.22
Service Logical IP Address of SysMgr:
120.120.13.22
Service Logical IP Address of AcctMgr:
120.120.13.22

20

Is this information correct? (y/n)
If the information is correct, press Y and Enter.

21

You are now configuring the Syslog daemon.

Press

Enter to continue.

22

Is this the Primary Accounting Server Machine in
a DUPLEX configuration [Y/N]?

Select N and Enter.

23

Press Enter to configure the LOM port.

You will need to enter the following information:

• IP address for the Physical Ethernet Net Management port

• Netmask for the Physical Ethernet New Management port

• Gateway IP address

Note: If the Net Management port was previously configured,
the IP address, Netmask address, and Gateway address are
shown as the defaults for the entries in steps 24, 25, and 26
below. Press Enter to accept the default IP addresses.

Advertising