Motor Control I/O Board User’s Manual


To control the motor from a GUI on your PC, connect a serial cable to the J9 RS-232 port on the

MC-IO board and rebuild the code with the GUI macro option as described later in this manual.

Figure 5. Standalone Operation

Three seconds after power up, the LED displays the current set speed.

Figure 6. Speed Display

4. Standalone Operation

After power up in standalone mode, the motor can be operated as follows:

1. Press

the

START/STOP button to run the motor.

2. Turn the potentiometer clockwise to accelerate or counterclockwise to decelerate.

3. Wait for the LED to display the actual motor speed calculated from the Hall sensor interrupts.

4. Press

the

FORWARD or REVERSE button to change the rotation direction.

5. Press

the

MODE button to display the set speed.

6. Press

START/STOP to stop the motor.

Note: If the potentiometer position is set to higher speeds, and the motor rotation is suddenly

reversed, an error condition may occur due to a timeout or over-current detection and the motor will

stop operating. To reboot, press the RESET switch on the MC-IO board, adjust the potentiometer to

a lower speed and restart.

5. Drive and Motor Protection

The starter kit and the motor are protected against unexpected events such as overload, motor stall

and malfunction of the Hall sensors. If such faults are detected, the motor stops rotating and the fault

4