Installing the NTAK09

Refer to

Table 74 "Shelf slot assignments for NTRB21, NTAK09, and

NTAK20" (page 202)

to determine the slot assignment for the NTAK09

DTI/PRI circuit card appropriate to the system.

The NTAK09 DTI/PRI card is installed only in the Media Gateway. It is not
supported in the Media Gateway Expansion.

Procedure 29

Installing the NTAK09

Step

Action

1

Check for available card slots in the base and expansion cabinets,
and Media Gateway systems and print the configuration record to
determine which slots can be used. To do this, enter the following
command in LD 22:

PRT CFN

2

Hold the NTAK09 by the lock latch, unlock the latch, and slide the
card into the cabinet.

Note: Refer to

Table 74 "Shelf slot assignments for NTRB21,

NTAK09, and NTAK20" (page 202)

to determine the correct slot

in which to insert the card.

—End—

The only cable required to support the NTAK09 DTI/PRI circuit card is the
NTBK04 cable. The cable is twenty feet long. If additional distance is
required, the NT8D97AX fifty-foot extension is available up to a 600 foot
maximum.

Table 76 "DS-1 line interface pinout for NTBK04 cable" (page

210)

gives pinout information for the NTBK04.

Procedure 30

Connecting the cables

Step

Action

1

Connect the NTBK04 cable to a 50-pin Amphenol connector on the
cabinet.

For a Small System, the Amphenol connector is located below the
card slot in which the NTAK09 circuit card is installed.

2

Connect the other end of the cable to the CSU or DSX-1 cross
connect.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.