On a maxi system, On a maxi system 13 – Nortel Networks Companion MICS-XC User Manual

Page 19

Advertising
background image

Planning the installation /

13

P0881594 Issue 01

MICS-XC Norstar-Companion Installer Guide

On a maxi system

A system expanded to 8 ports (maxi size) includes one 6-port
expansion cartridge with fiber ports numbered 3 to 8, and 1
and 2 on the ICS. The Base Stations

must

be physically

connected (via a Station Module) to fiber ports 7 and 8
only.There is a maximum number of two Station Modules per
Base Station. See “Six-port Expansion Cartridge with
Companion” on page 13.

If only one Station Module supporting Base Stations is
required, connect it to the highest-numbered port (port 8).

Six-port Expansion Cartridge with Companion

Tip -

If Both ports 7 and 8 are used for connecting

Station Modules supporting Base Stations, connect
Trunk Modules starting at port 6 and working down.
Connect Station Modules (for Norstar desk sets)
beginning at port 3 and working up.

SM3

SM4

SM5

SM6

ICS (modules 1 and 2)

TM8

SM7

p0881594.book Page 13 Tuesday, August 25, 1998 3:59 PM

Advertising