REPEAT 3100 Installation and Operation Manual

NAVMAN

6

+

+

Hold

+

Hold

+

5 sec

Increase value
or change
NMEA item

Decrease value
or change
NMEA item

Turn Simulate
on or off

Reset to factory
defaults

Adjust backlight
(4 levels or off)

Change display mode, between
Dual mode, Wind mode and
NMEA mode

Select NMEA
data to display

+

+

+

+

Return to
normal
operation

2-6 Key reference

Setup

Turn power on

Normal operation

Set Backlight
Group

NMEA Mode displays one item of data at a time from
any compatible NMEA instrument. To select which
NMEA data can be displayed, see section 5-2,
step 2. To change the item displayed, press

or

one or more times.

2-4 Changing units

To change the units on the REPEAT 3100, change
the units on the instrument which sends the data to
the REPEAT 3100.

Change item of data displayed

+

Set UTC offset
(for time display)

Turn NMEA
function display
ON or OFF

+

+

+

Change item of data displayed

2-5 Simulate

Simulate allows you to become familiar with the
REPEAT 3100 off the water. When simulate is on,
the unit functions normally except that the data from
other instruments is ignored and the unit generates
this data internally. The word SIM flashes at the
bottom, right corner of the screen if:

The REPEAT 3100 has simulate on.

Any instrument connected to the REPEAT
3100 by the NavBus has simulate on.

To turn simulate on or off in the REPEAT 3100:

1

Turn the power off.

2

Hold down

+

while you turn the power on.