Chapter 6

Automotive Diagnostic Command Set API for C

© National Instruments Corporation

6-93

Automotive Diagnostic Command Set User Manual

len

On input,

len

must contain the

DTCs

array length in elements. On return, it contains the

number of valid elements in the

DTCs

array.

success

Indicates successful receipt of a positive response message for this diagnostic service.

Return Value

The return value indicates the function call status as a signed 32-bit integer. Zero means the
function executed successfully. A negative value specifies an error, which means the function
did not perform the expected behavior. A positive value specifies a warning, which means the
function performed as expected, but a condition arose that may require attention.

Use the

ndStatusToString

function to obtain a descriptive string for the return value.

Description

This function executes the ReportDTCBySeverityMaskRecord subfunction of the UDS
ReadDiagnosticTroubleCodeInformation service and reads the selected DTCs.

For further details about this service, refer to the ISO 15765-3 standard.