3-34 Service Processor

Table 3-35. HC Subcommands (cont’d)

cmd arg1

arg2

arg3 arg4 Description

pcixx

-

-

-

Displays the state of the PCIV/PCIX Unit.

x” is the DGI/I2C cable port number (0-3) from
the iSP-C Board to the PCIV/PCIX Unit.

IOR0 is installed on the XIC Board. But the
IOR0 is displayed with the PCIX0(V) to realize
the same operation as the PCIX Unit.

disp
(cont’d)

pbayxy

-

-

-

Displays the state of the Power Bay/Power Bay
Unit.

x” is the chassis number.

0: Power Bay in the Main/Expansion Chassis
1: Power Bay Unit

y” is the ID number.

0 for the Power Bay in the Main Chassis
1 for the Power Bay in the Expansion Chassis
0 for the Power Bay Unit

-

-

-

-

Used to associate partition numbers to CELLV
Boards and IORs.

The number of CELLV Boards in a partition
must be the same or greater than the number of
IORs.

Displays Help for “attach” when the argument is
omitted or an error is made.

This subcommand can be executed in the DC
POWER OFF state of the partition.

When the online configuration and
deconfiguration function is released, this
restriction will be relieved.

attach

cellx

n m -

Associates the CELLV Board having the
physical number x with the logical CELLV Board
number m of partition n. (m: The number
recognizable by the BIOS and software.)

This command can also be used to change a
logical CELLV Board number if it has already
been associated.

Each logical CELLV Board number must be
unique among the CELLV Boards.

You cannot change the logical number of the
CELLV Board in the online state.

Advertising