Overheat, Table 4-4. configuration settings and effects, Considerations when connecting the digital i/o – National Instruments NI 1450 Series User Manual

Page 56

Advertising
background image

Chapter 4

Digital I/O Functionality

© National Instruments Corporation

4-11

NI 1450 Series Compact Vision System User Manual

Overheat

Operating the NI 1450 outside of its temperature specifications may cause
the NI 1450 to overheat. Refer to Appendix B,

Specifications

, for

temperature specifications.

In the event of an overheat, all NI 1450 operation halts and the
POWER OK LED turns red. If Shutdown mode is enabled, the outputs
go to the user-defined shutdown states.

Considerations When Connecting the Digital I/O

The isolated trigger inputs on the NI 1450 are current sinking and optically
isolated. Figure 4-6 shows the trigger input interface circuit.

Wiring an Isolated Input to a Sourcing Output Device

You can wire an isolated input to a sourcing output device, as shown in the
example in Figure 4-5. Refer to Appendix B,

Specifications

for switching

thresholds and current requirements.

Caution

Do not apply a voltage greater than 30 VDC to the isolated inputs. Doing so could

damage NI 1450.

Table 4-4. Configuration Settings and Effects

Fault

Condition

Configuration Settings

Configuration Effects

Safe Mode

DIP

Shutdown

Enabled

Processing Halts

Outputs Change to

User-Defined States

External
Shutdown

On

N/A

N/A

No

Off

On

Yes

Yes

Off

Off

No

No

Watchdog

On

N/A

N/A

No

Off

On

Yes

Yes

Off

Off

Yes

No

Overheat

On

N/A

Yes

No

Off

On

Yes

Yes

Off

Off

Yes

No

Advertising