Figure d-6. rtsi bus signal connection, Rtsi and pxi bus triggers – National Instruments 653X User Manual

Page 115

Advertising
background image

Appendix D

Hardware Considerations

© National Instruments Corporation

D-11

653X User Manual

RTSI and PXI Bus Triggers

The seven RTSI lines on the RTSI bus provide a very flexible
interconnection scheme for any device sharing the RTSI or PXI-trigger bus.
Any control signal on the device can connect to a RTSI or PXI-trigger bus
line. You can drive output control signals onto the bus and receive input
control signals from the bus. Figure D-6 shows the signal connection
scheme.

Note

If you configure a signal to be received from the RTSI bus, do not attach it to an

external source. Also, do not configure the 653X device to generate that signal internally.

Figure D-6. RTSI Bus Signal Connection

RTSI Bus or PXI Connector

Crossbar Switch

Trigger

20 MHz Timebase

REQ<1..2>

ACK<1..2>
(STARTTRIG<1..2>)

PCLK<1..2>

DAQ-DIO

STOPTRIG<1..2>

Switch

7

2

2

2

2