Sensus – New Media Technology Omnia ONE Multicast User Manual

Page 38

Advertising
background image

Adjusts the output level of the presence band limiter into the overall mix. Higher numbers result in
more presence frequencies and too much mix level can make the following final limiter work
unnecessarily hard.



Hi Band


Adjusts the output level of the high band limiter into the overall mix. Higher numbers result in

more high frequencies and too much mix level can make the following final limiter work

unnecessarily

hard.

<-Exit

Click on this option to return to the Adjust Processing submenu.



Sensus

®

Sen Freq (Sensus

® Frequency)


This sets the range where the SENSUS

® function begins its magic. For example, a setting of

5kHz will program the SENSUS

® algorithm to focus on frequencies of 5kHz and higher. You

should start with the 13kHz setting, and then select lower frequency settings until any coding
artifacts are tamed. There are 8 available adjustment frequencies between 13kHz and 1kHz.

Sen Level (Sensus

® Level)


Sets the amount of codec conditioning to be applied to the audio. Increasing the setting adds more

SENSUS

® control. Extreme settings -- those high enough to cause noticeable dulling of the

program material -- are unnecessary and will not further improve the audio quality through the

codec.

Ster Link (Stereo Link)

Under most operating modes, this can be set to Low or OFF. The link control allows dynamic
coupling of the stereo to mono ratio. When set to OFF, the Sensus

® function will only affect

mono material, or signals that are common to the Left/Right channels under stereo conditions.
Higher settings of the link adjustment may offer assistance with low bitrates and an inefficient
codec.

NOTE: While the Sensus

® Frequency and Sensus® Level controls are “algorithmically”

independent, from the standpoint of a codec they work in tandem to reduce coding artifacts
through a bit reduced system. Always start with the LPF (Low Pass Filter) (see Final Limit) set as
recommended by the table in that section. Then adjust Sensus

® Frequency and Sensus® Level

controls until satisfactory results are achieved through the codec.

<-Exit

Click on this option to return to the Adjust Processing submenu.

OmniaONE Multicast - Use and Operation Manual – Version 0.90