Bgd42cf vertical termination, 90° h, 45° h – Napoleon Fireplaces BGD36CFPTR User Manual

Page 17

Advertising
background image

17

W415-0661 / C / 02.20.08

BGD42CF VERTICAL TERMINATION

when (H

T

) < (V

T

)

Simple venting confi gurations

45°

MAXIMUM

VERTICAL

RISE IN FEET

V

T

HORIZONTAL VENT

RUN PLUS OFFSET IN

FEET H

T

The shaded area within the lines represents acceptable values
for H

T

and V

T

.

For vent confi gurations requiring more than one 45º and one 90°
elbow the following formulas apply:
Formula 1: HT < VT
Formula 2: HT + VT < 40 feet

Example 3:

90°

90°

90°

H

1

V

1

V

2

45°

H

2

V

1

= 5 ft

V

2

= 10 ft

V

T

= V

1

+ V

2

= 5 + 10 = 15 ft

H

1

=

3

ft

H

2

=

2.5

ft

H

R

=

H

1

+ H

2

= 3 + 2.5 = 5.5 ft

H

O

= .03 (one 45° elbow + three 90° elbows - 135°)

= .03 (45 + 90 + 90 +90 - 135) = 5.4 ft

H

T

=

H

R

+ H

O

= 5.5 + 5.4 = 10.9 ft

H

T

+ V

T

= 10.9 + 15 = 25.9 ft

Formula 1:

H

T

< V

T

10.9 < 15

Formula 2:

H

T

+ V

T

< 40 feet

25.9

<

40

Since both formulas are met, this vent confi guration is ac-
ceptable.

See graph to determine the required vertical
rise V

T

for the required horizontal run H

T

.

FIGURE 38

FIGURE 39