NuTone TWO-NOTE DOOR CHIME LB-76 User Manual

Model: lb-18, lb-76 series, Installation, Homeowner's information

Advertising
background image

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

Two-Note Door Chime

MODEL: LB-18, LB-76 SERIES

Designed for two-door operation.
Model LB-76 is designed to be used with a NuTone

Radio-Intercom system.

WIRING CAUTIONS: Before installing the transformer

and chime, turn off the house power and leave it off until
installation is complete.

Carefully fasten wiring to wall studs and ceiling joists

– avoid short circuits caused by staples or clips cutting
through the wiring's insulation. When drilling into walls,
be careful not to damage existing electrical cables.

All wiring must comply with local codes or the

National Electrical Code. If you are unfamiliar with
electrical wiring installation methods, secure the
services of a qualified electrician.

NOTE: NuTone Model 101T (16V - 15VA) transformer

is included with Model LB-76 Door Chime.

INSTALLATION

1. NuTone chimes are designed to be seen as well as heard.

Locate the chime on a wall at eye level.

2. Mount the transformer to a convenient junction box or

panel box. Connect the 120v AC house power leads to
the transformer wires as follows: black to black;
black to white.
NOTE: Label all wires as they are run.

3. Run 20-gauge, 2-conductor wire from the transformer

terminals to the chime site.

4. Wire and mount the pushbuttons. Run 20-gauge,

2-conductor wire from the pushbutton to the chime site.

5. If connecting Model LB-76 chime to a NuTone Radio-

Intercom, run NuTone IW-2 cable (22-gauge, 2-conductor)
from the Radio-Intercom to the chime site. For
connections to the Radio-Intercom, see instructions
packaged with the Radio-Intercom Master Unit.

6. Pull all of the wires which have been run to the chime site

through chime baseplate. Mount baseplate with supplied
screws.

7. Connect wires as shown in Figure 1. Where applicable,

make connections to Radio-Intercom as shown
in Figure 2.

8. Be certain the wires are not touching the chime tone bars

or the power unit.

9. Restore the house power to transformer and test chime.

If chime does not respond to pushbutton, check wire
connection.

10. Install the chime over the baseplate.

FIGURE 2

FIGURE 1

CHIME WIRING DIAGRAM

CAUTION: DO NOT USE THIS TRANSFORMER

FOR INTERCOM OR OTHER APPLIANCE

FRONT

TRANS

REAR

FRONT DOOR
PUSHBUTTON

20-GAUGE INSULATED
2-CONDUCTOR WIRE

COMMON
WIRES

120v AC
WIRING

NUTONE 101T
TRANSFORMER

REAR DOOR
PUSHBUTTON

INTERCOM CHIME VOLUME CONTROL

TERMINAL BOARD

1

2

NUTONE IW-2 CABLE

FROM RADIO-INTERCOM TO MODEL LB-76

HOMEOWNER'S INFORMATION

“Sluggish” chime plungers

If chime plungers should ever get “sluggish” in their

movement, clean the plungers with a non-flammable
cleaning fluid and wipe dry.

CAUTION: Never oil chime plungers.