405FX/405FXE HALF DUPLEX SETUP


While all RJ45 ports are Autosensing, the 405FX/405FXE Fiber Optic Port is factory configured for full
duplex operation. In the event half duplex operation is desired, follow these steps:

1.

Remove the Voltage Input Power Plugs.

2.

Remove the top cover (8 screws).

3.

Remove the jumper plug (JP1) from pins 1 and 2.

4.

Replace the top cover.

5.

Proceed with the installation.

Full Duplex = Pins 1 and 2 shorted.
Half Duplex = Remove jumper.

In order to verify the jumper settings have been set correctly, for units which have the N-View option turned
on
, you should install N-ViewOPC Server software on a PC connected to the LAN. The software is freely
distributed on the ProductCD and our web site (

http://n-tron.com/nview.zip

). Once N-ViewOPC is installed,

you should view the Ports Counter page to remotely monitor each connected port. You may find it helpful to
Copy [Alt]+[PrintScreen] the Port Counter information for each port and Paste [Control]+[V] into a Windows
document for further review. Please consult your N-View OPC Server Manual for additional information.