BEFORE YOU CALL A SERVICEMAN

1.

Make sure thermostat temperature selector
is set above room temperature for heating
or below room temperature for cooling. If
thermostat is equipped with heating/cool-
ing sub-base, make sure system switch
(see Figure 1) is set to “HEAT” for furnace
operation or set to “COOL” for optional air-
conditioning operation.

2. Check main household service panel to

see if appropriate circuit disconnect(s) for
appliance power supply is on.

3.

Refer to instructions under Before Operating
System for pre-operation checks.

4. Refer to instructions under Before Each

Heating Season for maintenance proce-
dures and recommended service checks.

5. Refer to owner’s manual provided with

optional air conditioner or heat pump (if
installed) for service and maintenance.

NOTE: All servicing of this heating appliance
other than the normal maintenance described in
this section must be done by authorized trained
service personnel. Do not open the control
panels (see Figure 1) at any time.

Please specify the complete model and serial
numbers shown on the furnace data label (see
Figure 1) for all warranty service and when or-
dering replacement parts or optional equipment.
Refer to the replacement parts list provided with
the furnace for part numbers.

OPTIONAL AIR CONDITIONER
AND HEAT PUMP

Your E3 Series electric furnace is approved for
use with an optional central air conditioner or a
heat pump. To adapt this heating appliance to
a “total comfort system,” contact your nearest
NORDYNE distributor.

Optional air conditioners and heat pumps are
listed by Underwriters’ Laboratories (UL) or
Environmental Testing Laboratories (ETL) and
certifi ed by ARI and the Canadian Standards
Association (CSA), or Warnock Hersey or ETLC.
These cooling systems include energy-sav-
ing components to provide maximum cooling
performance at electrical energy usage levels
established by federal standards. Refer to the
operation instruction label on your furnace for
the optional air conditioning equipment approved
for your heating appliance.

SECTION 2.

INSTALLER INFORMATION

GENERAL

These instructions and specifi cations are pri-
marily intended to assist qualifi ed individuals
experienced in the proper installation of home
heating and air conditioning appliances. Some
local codes require licensed personnel for the
installation and service of this type of equip-
ment. Approved installation, operation, and
maintenance of this central heating system
appliance must be in accordance with the listed
specifi cations contained in these instructions
and other documents supplied with the furnace
and/or optional air conditioning equipment. Refer
to local authorities having jurisdiction for further
information.

Before beginning installation, read these instruc-
tions thoroughly. Follow all warnings and cautions
in the instructions and on the unit.

Improper installation, service adjustment, or
maintenance can cause explosion, fi re, electri-
cal shock or other conditions which may result
in personal injury or property damage. Unless
otherwise noted in these instructions, use only
factory-authorized kits and accessories when
modifying this product.

Overview of E3 Furnace

E3E(-) Series electric furnaces are available in
two models. E3EH models are equipped with the
standard two-speed blower. E3EH models can
be easily converted for use with NORDYNE split-
system air conditioners and heat pumps. E3EB
models are air-conditioning ready; that is, they
are equipped with a multi-speed (four-speed)
blower, blower relay, and cabinet insulation kit.
See Table 3 for cooling and heat pump availability
with factory installed blower.

For typical unducted return air downfl ow applica-
tions, an air-conditioner or heat-pump coil can be
installed by mounting the coil directly on top of
the furnace without adding sheet metal cavities
or cutting and trimming wood panels.

A return air grille for closet or alcove installations
is available. For downfl ow alcove installations,
the grille (with frame provided) may be attached
to the top of the furnace and all paneling and
trim fl ushed to it. This installation provides an
access door for future installation of NORDYNE
air conditioning or heat pump coils on top of
the furnace.