Default features initial startup programming – NEC DSX-40 User Manual

Page 2

Advertising
background image

Default Features

Initial Startup Programming

1.

From any display telephone, press

INTERCOM

+ Dial

#*#*

+ Enter the system password +

HOLD.

2.

The system passwords are:

-

632379 (NECDSX)

for Installer (level 3),

9999

for System Administrator 2 (level 2),

0000

for System

Administrator 1 (level 1).

1.

In

3101-01: Line Type

, assign the line circuit type (e.g., enter

1

or press Feature Key 2 for loop start).

2.

In

3103-03: DTMF Dialing

, normally enter

1

(or press Feature Key 2) for DTMF dialing.

1.

In

2131-[01-64]: Line Access

, change each extension’s line access as required. The options are:

-

0

for no access,

1

for incoming access only,

2

for outgoing access only,

3

for full access

2.

Using

902x-Copy

may save you time.

1.

In

2132-[01-64]: Line Ringing

, set the ringing option for each extension, The options are:

-

0

for lamp only (no ringing) day and night,

1

for day and night ringing,

2

for night ringing only,

3

for delay

ringing day and night

2.

Using

902x-Copy

may save you time.

1.

Turn to the

System Programming Password Protection

feature to learn more about system passwords.

Default Features for Lines

1.

All lines are loop start DTMF.

Use

3101-01: Line Type

to change this assignment.

2.

Lines 1-8 ring on line keys 1-8 for extensions 300-315.

All other extensions are lamp only for lines 1-8.

3.

To customize line ringing, use one of the following:

User Programmable Features code

#RAL

. (See the

User Programmable Features

feature for more.)

Use

2132-[01-64]: Line Ringing

.

Default Features for Extensions

1.

The circuit types for keyset extensions are automatically set when the extension is plugged in.

2.

Keyset users can place outside calls by:

Pressing a line key and dialing the outside number. (See the

Central Office Calls, Placing

feature for more.)

Pressing

INTERCOM

, dialing 9, then dialing the outside number. (See the

Line Group Routing

feature for more.)

Line Dial-Up and Direct Line Access are disabled. (See the

Central Office Calls, Placing

feature for more.)

3.

All extensions have full incoming and outgoing access to all outside lines.

See

Initial Startup Programming

below to change this assignment.

4.

By default, Feature Keys 1-12 are line keys. Keys 13-24 are undefined. See the

Feature Keys

feature for more.

Default Features for IntraMail

1.

Each extension has an IntraMail voice mailbox.

2.

All mailboxes are enabled. To disable a mailbox, see

2141-01: Station Mailbox Type

.

3.

The IntraMail Automated Attendant does not answer outside calls. (See the

Automated Attendant

feature for more.)

1.

Enter the programming mode.

2.

Assign the correct circuit type to each of your installed lines.

3.

By default, each extension has full incoming and outgoing access to each line. To change this assignment:

4.

By default, extensions 300-315 ring immediately day and night for lines 1-8. To change this assignment:

5.

To change the default system passwords:

(1093067)

October 26, 2006, Rev 1
Printed in U.S.A.