ENGLISH / A-9

FORM NO. 56041978 - BR1100S / BR1300S - A-9

INSTALL THE BRUSHES (CYLINDRICAL SYSTEM)

CAUTION!

Turn the key switch off (O) and remove the key, before changing the brushes, and before opening any access panels.

1

Make sure the Scrub Deck is in the RAISED position. Make sure the Key Switch (A) is off (O).

2

See Figure 3. Remove both side skirt assemblies. NOTE: The skirts are held in place by two large Knobs (AA). Loosen these knobs, slide the Skirt
Assemblies (BB) forward slightly and then off of the Scrub Deck.

3

Loosen the Black Knobs (CC) on top of the Idler Assemblies (DD) until they drop down far enough to disengage from the Notches (EE) and remove.

4

Slide the brush into the housing, lift slightly, push and turn until it seats. Re-install the Idler Assemblies (DD) and Skirt Assemblies (BB).