INSTALLATION

ALL ELECTRICAL WORK MUST BE DONE IN ACCOR-

DANCE WITH LOCAL AND/OR NATIONAL ELECTRICAL

CODE AS APPLICABLE.
TURN OFF POWER AT SERVICE ENTRANCE BEFORE

INSTALLING, WIRING, OR SERVICING THIS PRODUCT.
1. Hold chime mechanism against wall and mark four (4)

mounting holes.

2. Drill 3/16” holes where marked and tap in wall anchors

from parts bag.

3. Bring wiring through access hole(s) in chime mechanism

backplate.

4. Loosely attach chime mechanism to wall with screws

from parts bag.

5. Tighten screws securely.

6. Connect wires to appropriate terminals.

7. Install two (2) alkaline 9-volt batteries, if appropriate for

your application. Turn on power at service entrance.

Make sure pushbuttons operate chime properly. (Ad-

just switch on circuit board for 4 or 8 chime tones at

front door. Side and rear doors will have 1 chime tone

each.)

8. Hook cover over chime mechanism.

THREE-NOTE

DOOR CHIME

READ AND SAVE THESE INSTRUCTIONS

battery

holders

wiring

access

hole

mounting

holes

DO NOT OIL CHIME PLUNGERS.

Oil will cause them to stick during operation. If plungers fail to operate freely due to accumulation of dust,

cooking grease, etc., clean with a non-flammable cleaning solvent which will evaporate, leaving a dry

surface.

RECOMMENDED NEW CONSTRUCTION WIRING

F

S

R

1

2

3

Lighted or

Unlighted Buttons

Front

Side

Rear

Ground

120 VAC

16 VAC

Transformer

NOT USED

Volume Control

9-volt

batteries

not used

OPTIONAL: 2 or 3 chimes can be connected to a single transformer. 2 chimes

require transformer Model C909 or C907. 3 chimes require transformer Model C907.