Nordyne Downflow Direct Vent Forced Air Gas Oil Furnaces SERIES M1B User Manual

Page 32

Advertising
background image

32

Table 12. A/C Blower Speed Selection Chart

M1/M5*B Models and for use with Blower Kit No. 903773 1/4 Hp 3 Speed

Furance Input

Heating Speed

Setting

Cooling Speed/ Evap Coil

2 Ton

2-1/2 Ton

3 Ton

086, 090

H

L

M

H

066, 070, 077

M

L

M

H

56

L

L

M

H

M1/M5*C Models and for use with Blower Kit No. 903413 1/2 Hp 4 Speed

Furance Input

Heating

Speed

Setting

Cooling Speed/ Evap Coil

2 Ton

2-1/2 Ton & 3 Ton

3-1/2 Ton

4 Ton

077, 086, 090

ML

L

ML

MH

H

056, 066, 070

L

L

ML

MH

H

M1/M5*D Models & for use with Blower Kit No. 903890 3/4 Hp 4 Speed

Furance Input

Heating

Speed

Setting

Cooling Speed/ Evap Coil

2 Ton

2-1/2 Ton & 3 Ton

3-1/2 Ton & 4 Ton

5 Ton

077, 086, 090

ML

L

ML

MH

H

056, 066, 070

L

L

ML

MH

H

Table 11. Equivalent Orifi ce Sizes for High Altitude Installations

FURNACE

MODEL

ORIFICE SIZE AND

OUTPUT CAPACITY

ALTITUDE - FEET

SEA

LEVEL

2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000

M1M/M1G

- 056

Orifi ce Size - Nat. Gas

29

29

30

30

30

30

31

31

31

32

Orifi ce Size - LP

45

46

47

47

47

48

48

49

49

50

Output - MBTUH

45.4

41.8 40.1 38.5 37.0 35.5 34.1 32.7 31.4

30.2

M1M/M1G

- 070

Orifi ce Size - Nat. Gas

24

25

26

27

27

28

28

29

29

30

Orifi ce Size - LP

42

42

43

43

43

44

44

45

46

47

Output - MBTUH

56.7

52.3 50.2 48.2 46.2 44.4 42.6 40.9 39.3

37.7

M1M - 077

Orifi ce Size - Nat. Gas

21

23

23

24

25

26

27

28

28

29

Orifi ce Size - LP

40

41

42

42

42

43

43

44

44

45

Output - MBTUH

61.7

56.9 54.6 52.4 50.3 48.3 46.4 44.5 42.7

41.0

M1G - 077

Orifi ce Size - Nat. Gas

21

23

23

24

25

26

27

28

28

29

Orifi ce Size - LP

40

41

42

42

42

43

43

44

44

45

Output - MBTUH

59.9

55.2 53.0 50.9 48.9 46.9 45.0 43.2 41.5

39.8

M1M - 090

Orifi ce Size - Nat. Gas

17

18

19

19

20

21

22

23

24

26

Orifi ce Size - LP

36

37

38

38

39

40

41

41

42

43

Output - MBTUH

71.7

66.1 63.5 60.9 58.5 56.1 53.9 51.7 49.7

47.7

M1G - 090

Orifi ce Size - Nat. Gas

17

18

19

19

20

21

22

23

24

26

Orifi ce Size - LP

36

37

38

38

39

40

41

41

42

43

Output - MBTUH

69.7

64.2 61.7 59.2 56.8 54.6 52.4 50.3 48.3

46.3

M1B - 066

Orifi ce Size - Nat. Gas

26

27

28

28

28

29

29

30

30

30

Orifi ce Size - LP

43

44

44

44

45

45

46

47

47

48

Output - MBTUH

52.6

48.5 46.6 44.7 42.9 41.2 39.6 38.0 36.5

35.0

M1B - 086

Orifi ce Size - Nat. Gas

18

19

19

20

21

22

23

24

26

27

Orifi ce Size - LP

37

38

39

39

40

41

42

42

43

43

Output - MBTUH

68.2

62.9 60.3 57.9 55.6 53.4 51.2 49.2 47.2

45.3

NOTES: For Canadian high altitude (2,000 - 4,500’), reduce gas manifold pressure to 3.0” W.C. for
natural gas and 9” W.C. for LP gas. (Includes 4% Input Reduction for Each 1,000 Feet). These specs
do not apply to oil furnace installations. Reference Sources: ANSI Z233.1 & NFPA 54, National Fuel
Gas Code.

Advertising