A-12 / english, Troubleshooting, Tripping the circuit breaker – Nilfisk-Advance America 18ST User Manual

Page 14: Poor water pickup, Inadequate solution flow, Ax 410, Revised 4/05

Advertising
background image

A-12 / ENGLISH

A-12 - FORM NO. 56041602 - AquaClean

/ AX 410

TROUBLESHOOTING

If the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your Nilfi sk-Advance Service
Center immediately for service.

TRIPPING THE CIRCUIT BREAKER

The Circuit Breaker (20) is located on the Control Panel; it protects the electrical circuit and brush motor from damage due to overload conditions. If
the circuit breaker is tripped try to determine the cause.
Brush Circuit Breaker (5 Amp) Possible cause may be:
1 Debris wrapped around the brush drive (remove debris)
2 Brush setting too low (adjust to proper brush setting)
3 Electrical short circuit (have your Nilfi sk-Advance Service Center or qualifi ed electrician check the machine)
Once the problem has been corrected, push the button in to reset the circuit breaker. If the button does not stay in, wait 5 minutes and try again. If the
circuit breaker trips repeatedly, call your Nilfi sk-Advance Service Center for service.

POOR WATER PICKUP

Possible causes may be:
1 Recovery Tank Full (empty recovery tank)
2 Open recovery tank drain hose (secure drain hose cap or replace)
3 Recovery hose not connected at vacuum shoe (connect hose to vacuum shoe)
4 Recovery hose is kinked or damaged (replace the hose)
5 Recovery tank cover gasket leak (replace gasket)
6 Debris caught in vacuum shoe or recovery hose (clean vacuum shoe and recovery hose)

INADEQUATE SOLUTION FLOW

Possible causes may be:
1 Solution tank empty (fi ll solution tank)
2 Solution lines or screen clogged (fl ush lines and screen)
3 Nozzle selector is turned to a position between maintenance and restoration (turn knob to full left or full right)

TECHNICAL SPECIFICATIONS (as installed and tested on the unit)

Model

AquaClean

16ST

AX 410

AX 410 J

AquaClean

16XP AquaClean

18FLX AquaClean

18ST

Model No.

56265002

56265007

56265003

56265001

56265008

56265000

Voltage/frequency

V/Hz

220-240 / 50-60

100 / 50-60

120 / 50-60

120 / 50-60

120 / 50-60

Rated Current

Amp

7

13.3

13.3

14

14

Protection Class (electrical)

Protection Grade

IP34

--

--

--

--

Sound Pressure Level (IEC 60704-1)

dB (A)/20μPa 74.3

74.3

74.3

74.3

74.3

Total Weight

lbs/kg

166 / 75.29

166 / 75.29

166 / 75.29

203 / 92

203 / 92

Vibrations at the Hand Controls (ISO 5349-1)

m/s

2

0.72m/s

2

0.72m/s

2

0.72m/s

2

0.72m/s

2

0.72m/s

2

Solution Tank Capacity

8 gal (30l) 8

gal

(30l) 8

gal

(30l) 11

gal

(41l) 11

gal

(41l)

Recovery Tank Capacity

6 gal (23l) 6

gal

(23l) 6

gal

(23l) 9

gal

(34l) 9

gal

(34l)

revised 4/05

revised 10/06

Advertising