Rs232 interface – Network Technologies SM-nXm-C5AV-LCD User Manual

Page 18

Advertising
background image

NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5

14


This function is particularly useful to determine if a lack of sound from speakers is due to failed speakers, or lack of audio signal
through the VEEMUX. If no signal is seen in this display, check all connections between the audio source, the XTENDEX, and
the respective Input port on the VEEMUX.

Pressing <Esc> again will return to the connections display.

RS232 Interface

A user may control the VEEMUX using an RS232 interface by connecting a PC to the DB9 female connector on the VEEMUX
labeled "RS232". Using a program such as HyperTerminal or the Matrix Switcher's Control Program (page 15), the VEEMUX
can be setup and controlled.

When using HyperTerminal (or a similar program), configured at the same baud rate as in the VEEMUX (default is 9,600), 8 bits,
no parity, no flow control, the VEEMUX can be controlled by sending the commands in the following chart,

where:

SW = the Switch Serial Address
<CR> = the Carriage Return character
IP = the input port
OP = the output port
ip = the IP address

Command

Answer

Description

CS SW,IP,OP

*<CR>

Connect One Input (Audio/Video Source) to Output (User Port)

CA SW,IP

*<CR>

Connect All Outputs To Input

RO SW,OP

*<CR>IP<CR>

Read Connection For Output

CC SW,xx

*<CR>xx<CR>

Save Matrix Connections Into Memory Bank xx

xx= 00-09

RC SW,xx

*<CR>xx<CR>

Restore Matrix Connections From Memory Bank xx

Xx=00-09

CB 00,nn

none

Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)

Factory default is 9,600

RV SW,00

*<CR>string\0<CR>

Read NTI Version String

RU SW

*<CR>IP,OP<CR>

Read Unit Size

EA SW,ip

*<CR>

Set the IP address, ip is in xxx.xxx.xxx.xxx format,

number of digits is minimum 1 and maximum 3 for each field

Leading zeroes are accepted

EM SW,ip

*<CR>

Set the Subnet mask, ip is in xxx.xxx.xxx.xxx format,

number of digits is minimum 1 and maximum 3 for each field.

Leading zeroes are accepted

EG SW,ip

*<CR>

Set the default gateway, ip is in xxx.xxx.xxx.xxx format,

number of digits is minimum 1 and maximum 3 for each field

Leading zeroes are accepted

ET SW,timeout

*<CR>

Set the website timeout; timeout = numeric string of timeout in

seconds.

Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800

RA SW

*<CR>ip<CR>

Read the IP address, ip is in xxx.xxx.xxx.xxx format,

number of digits is minimum 1 and maximum 3 for each field

Leading zeroes are accepted

RM SW

*<CR>ip<CR>

Read the Subnet mask, ip is in xxx.xxx.xxx.xxx format,

number of digits is minimum 1 and maximum 3 for each field

Leading zeroes are accepted

RG SW

*<CR>ip<CR>

Read the default gateway, ip is in xxx.xxx.xxx.xxx format,

number of digits is minimum 1 and maximum 3 for each field

Leading zeroes are accepted

RT SW

*<CR>timeout<CR>

Read the website timeout; timeout = numeric string of timeout in

seconds.

Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800



If the first field is not a known command (as listed above) or SW field is different from the serial address programmed in the switch
memory, the command will be ignored. If the SW field corresponds to the serial address, but the syntax is wrong after this field,
the switch will answer with ?<CR>.