Typical installation, Certified test data – NuTone VENT-A-LITE 668RP User Manual

Page 2

Advertising
background image

CERTIFIED TEST DATA

HVI-2100 CERTIFIED RATINGS comply with new

testing technologies and procedures prescribed by the
Home Ventilating Institute, for off-the-shelf products, as
they are available to consumers. Product performance is
rated at 0.1 in. static pressure, based on tests conducted in
AMCA's state-of-the-art test laboratory. Sones are a
measure of humanly-perceived loudness, based on
laboratory measurements. This NuTone model is listed by
Underwriters' Laboratories Inc.

The air delivery of a ventilating system may be
determined by:
1. Determine the equivalent duct length for each 90 degree

elbow by adding one foot of duct length for each inch of
duct diameter, i.e., a 4 inch diameter duct elbow equals
4 feet equivalent duct length and an 8 inch diameter
duct elbow equals 8 feet equivalent duct length.

2. Add the total straight length of duct and the equivalent

length for each elbow to obtain the total equivalent
duct length.

3. Locate the intersection of the fan performance curve and

the total equivalent duct length curves and draw a
vertical line down to the CFM scale and read the system
air performance.
(NOTE: 3

1

4

" x 10" duct equals 6 inch diameter duct.)

100

50

0

0.00

0.10

0.20

0.30

0.40

0.50

ST

A

TIC PRESSURE–INCHES OF W

A

TER

50 Feet

40 Feet

30 Feet

20 Feet

10 Feet

CFM CUBIC FEET PER MINUTE

75

125

25

AIR PERFORMANCE CURVE

(4 In. Duct to 10 Foot Lengths)

STATIC PRESSURE
INCHES OF WATER

CFM

0.05

77

75

72

70

67

64

60

54

47

0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45

LIGHT
SOCKET

REFLECTOR
MOUNTING
SCREW

TYPICAL INSTALLATION

Product specifications subject to change without notice.

NuTone, Inc., 4820 Red Bank Road, Cincinnati, Ohio 45227

Printed in U.S.A.