Norton Abrasives C6136 User Manual

Page 45

Advertising
background image

45

to form sludge), foaming and water settling to the bottom of the
reservoir. Fifth, the oil must be able to pour or flow at the lowest
expected temperature so that the oil can reach or get into the pump.
For all of the reasons just listed, automatic transmission fluid (ATF
Dextron B) was found in most cases to be the best readily available
fluid for the job in most climate conditions.

b. Selecting Fluids for Applications Outside of a TFS Temperature Range

When looking for fluids that can be used in the place of automatic
transmission fluid or for applications where the operating temperature
is outside of the range of automatic transmission fluid, the following
specifications should be discussed with your local oil distributor:

1. Fluid must be compatible with Buna N sealing compounds.

2. The Pour Point must be below the lowest anticipated temperature that will

be encountered.


3. It should contain rust and Oxidation as well as other detergent type

inhibitors.


4. The Viscosity (SUS) should lie between 80 as a minimum and 375 as a

maximum in the operating range with the ideal viscosity near 200 SUS.


5. The viscosity index should be as high as possible.

As an example, automatic transmission fluid (ATF) has the following
specifications as listed by most oil manufacturers.
A. Viscosity (SUS) 185 to 205 @ 100OF

Viscosity (SUS) 45 to 50 @ 210OF

B. Pour Point 450F to 350F.
C. Viscosity Index 145 to 165
Note: In an emergency for cold weather applications SAE 1OW non
detergent oil mixed by volume with no more than 30% #1 fuel oil or
kerosene can be used.

11. Hydraulic Pump Priming

A. New Installations:

New system installations, as well as those that are disassembled
for repair, require proper priming to avoid possible pump failure. A
pump is said to be "primed" when the internal cavity is full of oil
and the air has been expelled. If needed, prime a pump as follows:

1. "Crack" or remove the high pressure line at or near the

cylinder.

2. "Jog" the handle until oil flow is clear. (Air is absent.)
3. Retighten or replace hose.

Advertising