GAS HOOK-UP

NEVER CONNECT AN UNREGULATED
GAS SUPPLY LINE TO THE APPLIANCE.
USE THE REGULATOR/HOSE ASSEMBLY
SUPPLIED.

This is a liquid propane configured grill. Do
not attempt to use a natural gas supply unless
the grill has been reconfigured for natural gas
use.

Total gas consumption (per hour) of this
stainless steel gas grill with all burners on
“HI”:

Main burner

48,000 Btu/hr.

Side burner

12,000 Btu/hr.

Rear burner 10,000 Btu/hr.
Total

70,000 Btu/hr.

L.P. TANK REQUIREMENT

A dented or rusty L.P. tank may be hazardous
and should be checked by your L.P. supplier.
Never use a cylinder with a damaged valve.
The L.P. gas cylinder must be constructed and
marked in accordance with the specifications
for L.P. gas cylinders of the U.S. Department
of Transportation (DOT) or the National
Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres and Tubes for
Transportation of Dangerous Goods; and
Commission, as applicable. Overfilling
prevention device (OPD) shall be provided on
cylinder & QCCI connection on the cylinder
valve, ANSI/CGA-V-1. The cylinder supply
system must be arrange for vapor withdrawal.
The cylinder must include a collor to protect
the cylinder valve. The cylinder must be
provided with a shut off valve terminating in
an L.P. gas supply cylinder valve outlet
specified, as applicable, for connection type

QCC1 in the standard for compressed gas
cylinder valve outlet and inlet connection
ANSI/CGA-V-1.

Manifold pressure: (operating): 10” water
column (W.C.), (non-operating): 11.2” water
column (W.C.).

L.P. GAS HOOK-UP

Ensure that the black plastic grommets on the
LP cylinder valve are in place and that the hose
does not come into contact with the grease tray
or the grill head.

CONNECTION

Your stainless steel grill is equipped with gas
supply orifices for use only with liquid propane
gas. It is also equipped with a high capacity
hose/regulator assembly for connection to a
standard 20lb. L.P. cylinder (18-1/4” high, 12-
1/4” diameter).

To connect the L.P. gas supply cylinder, please
follow the steps below:

1. Make sure tank valve is in its full off

position (turn clockwise to stop)

2. Check tank valve to assure it has proper

external male threads (type 1 connection
per ANSIZ21.81)

3. Make sure all burner valves are in their off

position.

4. Inspect valve connections, port, and

regulator assembly. Look for any damage or
debris. Remove any debris. Inspect hose for
damage. Never attempt to use damaged or
obstructed equipment. See your local L.P.
gas dealer for repair.

5. When connecting regulator assembly to the

12