Architectural & Engineering Specifications

October 2009

Humidity Sensing

Recessed

Fan / Fluorescent

Light

90K

99044573A

DESCRIPTION

TRIM RING BAFFLE:

Polymeric construction with matte white finish

Recessed styling, mounts flush with finished ceiling

Integrated humidity sensor

LAMP:

Uses R30-shaped, 3500K, 14W, high efficacy, compact

fluorescent lamp with GX24q-1 base (included)

Electronic ballast

BLOWER:

Plug-in, permanently lubricated, motor

Dynamically balanced centrifugal blower wheel for quiet,

efficient performance

Quiet operation

HOUSING:

Fits in 2” x 8” construction

Rugged, 26 gage, galvanized steel construction

4” round, polymeric duct connector with 2” tapered sleeve and

no metallic clatter

Adjustable mounting brackets span up to 24”

CONTROLS: (purchase separately)

Model VS-96 - One rocker switch with “on” indicator light

Model VS-86SN - Two rocker switches - fits single outlet box

AUTOMATIC CONTROL:

Humidity control automatically turns fan ON when either of

these conditions is detected:

- a rapid to moderate (user adjustable) increase of humidity

- humidity above user-adjustable set-point (50%-100% RH)

Two wire manual operation for odor control - Turns fan ON

when power line through wall switch is cycled ON, OFF and

back ON

Remains ON for a user-adjustable 5 to 60 minutes after

humidity has stabilized and is below set-point or after

manually initiated through power line cycling

Saves energy because unit runs only for the time required. A

unit controlled with a wall timer may keep fan ON longer than

required or turn it OFF before room is sufficiently ventilated

U.L. Listed for use in insulated ceilings (TYPE I.C.)

U.L. Listed for use over bathtubs and showers when connected to

a GFCI protected branch circuit.

Title 24 compliant.

ENERGY STAR qualified.