installation

4-2

Preparing the Site

Before you install your switch, be sure your operating environment meets the operating
environment requirements in Table 4-1.

Table 4-1. Site Requirements

Characteristics Requirements

Mounting

Desktop installations:

Provide a flat table or shelf surface.

Rack-mount installations:

Use a 19-inch (48.3-centimeter) EIA standard equipment rack that is
grounded and physically secure. You also need the rack-mount kit supplied
with your switch.

Access

Locate the switch in a position that lets you access the front panel RJ-45
ports, view the front panel LEDs, and access the rear-panel stacking port(s)
and power connector.

Power source

Provide a power source within 6 feet (1.8 meters) of the installation
location. Power specifications for the switches are shown in Appendix A. Be
sure the AC outlet is not controlled by a wall switch, which can accidentally
turn off power to the outlet and the switch.

Environmental

Install the switch in a dry area, with ambient temperature between 0 and

Temperature:

40ºC (32 and 104ºF). Keep the switch away from heat sources such as
direct sunlight, warm air exhausts, hot-air vents, and heaters.

Operating humidity:

The installation location should have a maximum relative humidity of
90%, non-condensing.

Ventilation:

Do not restrict airflow by covering or obstructing air inlets on the sides of
the switch. Keep at least 2 inches (5.08 centimeters) free on all sides for
cooling. Be sure there is adequate airflow in the room or wiring closet where
you intend to install the switch.

Operating conditions:

Keep the switch at least 6 ft (1.83 m) away from nearest source of electro
magnetic noise, such as a photocopy machine.

After confirming that your site meets the requirements in Table 4-1, you are ready to
install the switch.