Input, Figure 8 - dual busmatrix – Niles Audio SI-1260 User Manual

Page 13

Advertising
background image

12

APPLICA

TIONS & SYSTEM DESIGN CONSIDERA

TIONS

Utilizing the Dual BusMatrix

Input

Many multi-zone systems incorporate multiple rooms within a single zone. The
SI-1260’s Dual BusMatrix

Input simplifies the connections required for this system

design. As shown in Figure 8, a Niles A4.6Ci Multi-zone Controller has its first and
second zone outputs connected to the SI-1260’s Dual BusMatrix

#1 and #2 inputs

respectively. Bus Input #1 is then routed to amplifier channels one through six via
dip switch settings. Bus Input #2 is routed to amplifier channels seven through twelve
in the same manner. Six rooms can now be connected to the
SI-1260 placing three rooms in Zone #1 and three rooms in Zone #2. The remain-
ing zone outputs on the A4.6Ci can be connected to another SI-1260 for more zones.

DVD/CD

CHANGER

DSS

SI-1260

SI-1260

Niles A4.6Ci

ZONE 1

ROOM 1

ROOM 2

ROOM 3

ROOM 4

ROOM 5

ROOM 6

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 2

Zones 3-6

Zones 1-2

BusMatrix Input 1

Niles VCS-2D

Volume Control

AM/FM

TUNER

BusMatrix Input 2

Figure 8 - Dual BusMatrix

Input