— an alarm message is created in the alarm log and the MMI terminal

— the LEI card enters line-conditioning mode

— a yellow alarm message is sent to the CPE/LTU

Line processing sends the CS 1000S, CS 1000M, and Meridian 1 either all
“on-hook” or all “off-hook” signals, depending on the dip switch setting of
the card. See Table 99 on

page 270

.

When the Set Alarm command is selected, the prompt appears for setting
the threshold level and duration for alarm levels 1 and 2.

The E1 link processes at a rate of approximately 2.0 mb/s. The threshold
value indicates the ratio of the total number of bits that must be detected as
being in error per second before the LEI activates an alarm. It can be set
between 3 and 9 and can be different for each alarm level. Any other value
entered will cause the MMI to display a “Parameter Invalid”
message. The digit entered as the threshold value is a number representing a
negative power of 10 as shown in Table 106.

Note: The error-rate threshold for a level 2 alarm must be greater (a
smaller power of 10) than for a level 1 alarm. Remember that the
numbers being represented are negative numbers. Since 3 represents –3,
and 4 represents –4, 4 represents a smaller number than 3 does.

Table 106
E1 bit error rate threshold settings (Part 1 of 2)

Alarm threshold bit

errors per second in

power of 10

Threshold to set

alarm

Allowable Duration

Periods

10

-3

2,000/ second

1-21 seconds

10

-4

200/second

1-218 seconds

10

-5

20/second

1-2148 seconds

10

-6

2.0/second

1-3600 seconds

10

-7

2.0/10 seconds

10-3600 seconds