SCXI-1190/1191/1192 User Manual

Expected life

Mechanical (no load)

...................... 5 × 10

6

operations

Electrical at maximum
switching capacity........................... 10

5

operations

Caution

Exceeding the maximum switching capability decreases the expected life of the

SCXI-1190.

Power Requirement

+5 VDC

Maximum (all relays closed) .......... 600 mA

Physical

Dimensions............................................. 17.30 by 19.56 by 3.02 cm

(6.81 by 7.70 by 1.19 in.)

I/O connectors ........................................ 5 SMB male per bank;

4 banks

Environment

Operating temperature ..........................0 to 50

°C

Storage temperature..............................–20 to 70

°C

Relative humidity ................................... 10% to 90% noncondensing

Electromagnetic Compatibility

EMC/EMI............................................... CE, C-Tick, and FCC Part 15

(Class A) Compliant

Electrical emissions................................ EN 55011 Class A at 10 m

FCC Part 15A above 1 GHz

Electrical immunity................................ Evaluated to EN 61326-1:1997

A1:1998, Table 1

Note

For full EMC and EMI compliance, you must operate this device with shielded

cabling. See the Declaration of Conformity (DoC) for this product for any additional
regulatory compliance information. To obtain the DoC for this product, click
Declaration of Conformity

at

http://www.ni.com/hardref.nsf/