页 11, Operation, When heater is on – Napoleon Grills PROPANE PATIO HEATER SRPH01 User Manual

Page 11: Handle with extreme care, The event of gas leakage, Fermeture

Advertising
background image

OPERATION

11

OPERATION

When lit for the first time the heater may emit a slight odor and smoke. This is a
normal temporary condition caused by the “burn in” of paints and lubricants
used in the manufacturing process and will not occur again. Simply run the
heater on “high” for 30 minutes.

The burner may be noisy when initially turned on. To eliminate excessive noise from the burner,
turn the Control Knob to the “LOW” position. Then turn the knob to the level of heat desired.

When heater is ON:

Emitter screen will become bright red due to intense heat. The color is more visible at night.
Burner will display tongues of blue flame. These flames should not be yellow or produce thick
black smoke, indicating an obstruction of airflow through the burners.

1) Turn the control knob to “OFF” position.
2) Wait five (5) minutes before attempting to relight pilot.
3) Repeat steps beginning with step 3 on page 10.

Never leave the heater unattended while in use.

Follow the Shut Down Instructions outlined below.

SHUT DOWN INSTRUCTIONS

1) Push in and turn control knob clockwise to "OFF" position.
2) Turn off the natural gas supply valve.

Note: After use, some discoloration of the emitter screen is normal.

Handle with extreme care.

2"

1"

0"

Pus

h to

tu

rn

OFF

H

GI

H

LO

W

TO

LI

P

Pus

h to

tu

rn

OFF

H

GI

H

LO

W

TO

LI

P

The Event of Gas Leakage

1) Turn the control knob to “OFF” position.
2) Wait 5 minutes to allow gas to dissipate.
3) If odor continues, immediately call gas supplier.

Operation Pressure Checked
If the flame is very small, this is because the supply pressure is not enough.

If you experience any ignition problem, turn off the heater and gas supply, and consult

“Troubleshooting" on page 14.

Note: The flame pattern at the emitter grid should be visually checked whenever the heater is
operated. Normally the burner flame is blue, but little yellow flame is acceptable.
If flames extend beyond the surface of the emitter grid, flame is lifting off the or there is a black
soot (carbon) accumulating on the emitter grid or reflector, the heater should be turned off
immediately. The heater should not be operated again until services and or replaced.

FERMETURE

1) Poussez et tournez le bouton de réglage vers la droite à “OFF”
2) Fermez complétement la soupape de réservoir de propane ou de l’approvisionnement en gaz
naturel.

Note: After use, some discoloration of the emitter screen is normal.

Advertising