5. Troubleshooting

Troubleshooting guide

Trouble Possible

cause

Solution

PWR indicator does
not light up after

Turning on the
power.

Power outlet, power cord,
or internal power supply

may be defective.

• Check the power outlet by plugging in

another device that is functioning

properly.

• Check the power cord with another

device.

SYS indicator does
not light up after

startup.

Microprocessor, SDRAM,
Flash or Software may be

defective.

• Verify that the switch are powered on.
• Check the boot-up statement from

console. The boot up procedure is Boot
-> kernel->application

ADSL2+ LINK
indicator does not

light up after making
a connection.

NCT240 Switch, cabling,
ADSL Line, or ADSL Switch

Ports may be defective.

• Verify that the Access Switch and

attached CPE are powered on.

• Be sure the RJ-21 cables are plugged

into the Access Switch from ADSL2+

modem through the Phone-line
punch-down block.

• Verify that the cable length does not

exceed specified limits.

• Check the cable connections on the

access Switch, punch-down block/patch

panel, and the Extended Ethernet CPE
for possible defects. Replace the

defective cable if necessary.

UP LINK indicator
does not light up

after making a
connection.

Network cable or Ethernet
device attached to this

port may be defective.

• Verify that the access switch and

attached device are powered on.

• Be sure an Ethernet cable is plugged into

both the switch and attached device.

• Verify that the proper cable type is used

and its length does not exceed specified

limits.

• Check the network cable connections

for possible defects. Replace the
defective cable if necessary.