Nordyne M3RL Series User Manual

Page 12

Advertising
background image

12

TABS

TABS

DUCT

DUCT

1. INSERT DUCT PLENUM CONNECTOR
INTO DUCT CUT-OUT.

2. BEND BOTTOM TABS OVER
AND ONTO THE UNDERNEATH
DUCT SERVICE.

Staple Folded Duct

Flap (typ) to side of Duct

Connector

Duct

STEP 4.

STEP 1.

"A"

"A"

"B"

"B"

Cut- Out
Area"A"

Cut- Out

Area "A"

Fold Back Flap "B"

Fold Back Flap "B"

Top of Duct

"A"

"A"

STEP 2.

"B"

"B"

Fold Back Flap"B"

Cut

Lines

Duct

Fold Back Flap"B"

STEP 3.

Bend Duct Connector Tabs Up

and Over- (along length of duct)

Duct
Flap "B"

Duct

Duct

Duct Connector

Narrow Duct

Figure 12. Alternate Installation

Figure 11. Narrow Duct Installation

Figure 10. Installation of Duct Connector

nector. Additional screws may be added if
required.

e. Cut away along edge of flange allowing the

center to drop into the duct. Remove section
of duct with caution, as edges will be sharp.

INSTALLING FINGER TABBED DUCT CON-
NECTORS
a. Place duct connector through the floor open-

ing with bottom tabs extending through the
duct opening. (See Figure 9)

b. Secure duct connector to floor.
c. Bend bottom tabs under and up tightly against

the supply air duct (See Figure 10).

NOTE: The duct connector is designed for use
on ducts 12" in width. When using the connec-
tor on 12" wide ducts, there may be insufficient
clearance to bend the tabs on two sides of the
duct connector. In such cases the tabs may be

attached to the sides of the duct by using sheet
metal screws or other suitable fasteners. (See
Figure 11).

If sealant, mastic, or tape is used to provide a
better seal, it should be approved by applicable
national or local codes.

ALTERNATE ATTACHMENT METHODS

This procedure may also be used to install a
furnace duct connector to narrow metal
ductwork where insufficient clearance prevents
bending of the duct connector tabs at the
side(s) of the duct. (See Figure 12).
1. Score and cut the top of the metal duct as

indicated in Step 1 or Step 2. With Step 1
choice, also cut out the metal from the shaded
area “A”.

2. Fold the duct flap “B” up, (See Step 3).

Advertising