6800/7000 Series - Distribution and Routing Products Installation and Operation Manual

61

Configuration

Chapter 7: VEA-6840 Video Equalizing Amplifier Module

Configuration

Figure 7-2.

Coupling and Clamp Configuration Options

Input Coupling

• For AC coupling: Place J2 and J3 in the upper position, as illustrated

above.

• For DC coupling: Place J2 and J3 in the lower position, as illustrated

above.

Clamp Mode

Clamping can be set to No Clamp, Hard, or Soft clamp via Jumper J1, as
illustrated above.

DC

AC

J3

J3

J2

J2

Input Coupling

J3

J3

J3

SOFT

HARD

NO

CLAMP

Clamp Mode

Shunt positions for Clamp
Mode a

nd Input Coupling are

illustrated by the symbols
printed on the circuit board.