Speed selection and controls, Optional remote controls, Dehumidistat ventilation control (dvc) – Lifebreath 500ERV User Manual

Page 19: Dehumidistat, Supplied and installed by contractor, 60 minute crank timer

Advertising
background image

19

These models are equipped with a 3 speed
control, low medium and high, as well as a
lighted on/off switch and a 4 screw terminal strip.
The terminal strip can be used to connect any
low voltage device which will then jump the unit
to high speed from whatever setting the speed
control was on. The terminal strip can also be
wired to allow the unit to be turned off from a

remote location as well as from high to low from
a remote location. To wire the unit in this
configuration you would need two electrical on/off
switches to be installed at the remote location
into a double gang electrical enclosure or side by
side. One should be labeled on/off and the other
should be labeled high/low.

Off

10

20

30

40

50

60

DEHUMIDISTAT VENTILATION

CONTROL (DVC)

PART NO. 99-116

•Turns ERV ON/OFF

• Dehumidistat increases

ventilation when required

Speed Selection and Controls

Model 700, 850 and 1200 HRV/ERV only

DEHUMIDISTAT

PART NO. 99-130W

•Provides high speed

ventilation when humidity

level exceeds setting

ON

OFF

LOW

HIGH

ON

OFF

LOW

HIGH

Optional Remote Controls

ON/OFF/LOW/HIGH

SWITCHING FROM REMOTE LOCATION

LOW/HIGH ONLY

ON/OFF ONLY

ON/OFF SWITCH

3 SPEED CONTROL

*Supplied and Installed by Contractor*

COMMON

ON/OFF

HIGH

RED BLACK ORANGE

Dehumidistat

Setting Relative to

Outside Conditions

WINTER:

Set dehumidistat

between 30% to 40%.

If home is too dry,

adjust to higher setting.

If home is too humid,

adjust to lower setting.

SUMMER:

Set dehumidistat

to OFF.

60 MINUTE CRANK TIMER

PART NO. 99-101

•Provides high speed

ventilation for 60 minutes

This style of remote switching began
approximately July 1997