6. POWER UNIT INSTALLATION

6.1 LOCATING THE POWER UNIT

• Locate the power unit away from the general living area in an accessible

location for cleaning and maintenance.

• Locate the power unit within 6 feet of a grounded electrical outlet. The power

unit requires a 120 VAC power source.

• Do not locate the power unit close to a source of extreme heat (i.e.: water

heater) or in an area with a high ambient temperature (i.e.: attic, furnace room).

• Do not locate the power unit where the temperature can drop below 0°C (32°F).
• If the power unit is located in a closet or a small utility room, make sure the area

is well-ventilated (i.e.: with door louvers).

NOTE: Refer to NuTone website for information on tubing installation

(www.nutone.com).

6.2 MOUNTING POWER UNIT

1. Carefully remove debris pail from power

unit. Make sure bag is properly installed in
power unit. Remove accessories and
installation kit. Securely reinstall pail.

2. Install the 3-way elbow on the back of the

power unit and press firmly (do not glue).
Remove the plastic cap from the inlet
opening only if your installation requires the
connection into both inlets.

3. Install mounting bracket on a wall stud within

6 feet of a grounded electrical outlet, at the
distances specified on illustration beside.
Ensure that wall between mounting bracket
and inlet is straight and leveled.

- 6 -

MINIMUM WALL CLEARANCE

DIMENSIONS

TOP VIEW

FRONT VIEW

INLET

CEILING

EXHAUST

FLOOR

INLET

INLET

AD0043A

WALL

BRACKET

12"

MINIMUM

TO

CEILING

30"

18"

MINIMUM

ABOVE

FLOOR

50"

12"

14"

MIN

.

PVC

TUBING

STRAP

INLET

EXHAUST

AO0034

CAUTION

Make sure to assemble the wall mounting
bracket with the screws directly onto a
wall stud for a solid installation.

3-

WAY ELBOW

DO NOT GLUE

R

EMOVE

PLASTIC CAP

(

IF NEED BE

)

Advertising