PC Control Codes and Cable Connections

The following table shows PC functions and their associated code data.

F

UNCTION

C

ODE

D

ATA

POWER ON

02H 00H 00H 00H 00H 02H

POWER OFF

02H 01H 00H 00H 00H 03H

INPUT SELECT COMPUTER 1

02H 03H 00H 00H 02H 01H 01H 09H

INPUT SELECT COMPUTER 2

02H 03H 00H 00H 02H 01H 02H 0AH

INPUT SELECT COMPUTER 3

02H 03H 00H 00H 02H 01H 1AH 22H

INPUT SELECT COMPONENT

02H 03H 00H 00H 02H 01H 10H 18H

INPUT SELECT VIDEO

02H 03H 00H 00H 02H 01H 06H 0EH

INPUT SELECT S-VIDEO

02H 03H 00H 00H 02H 01H 0BH 13H

PICTURE MUTE ON

02H 10H 00H 00H 00H 12H

PICTURE MUTE OFF

02H 11H 00H 00H 00H 13H

SOUND MUTE ON

02H 12H 00H 00H 00H 14H

SOUND MUTE OFF

02H 13H 00H 00H 00H 15H

ON-SCREEN MUTE ON

02H 14H 00H 00H 00H 16H

ON-SCREEN MUTE OFF

02H 15H 00H 00H 00H 17H

ASPECT RATIO

4:3

03H 10H 00H 00H 05H 18H 00H 00H 00H 00H 30H

16:9

03H 10H 00H 00H 05H 18H 00H 00H 02H 00H 32H

15:9 (NP4001 only)

03H 10H 00H 00H 05H 18H 00H 00H 06H 00H 36H

Letterbox (NP4001 only)

03H 10H 00H 00H 05H 18H 00H 00H 01H 00H 31H

Crop (NP4000 only)

03H 10H 00H 00H 05H 18H 00H 00H 03H 00H 33H

AUTO ADJUST

02H 0FH 00H 00H 02H 05H 00H 18H

Note:

Contact your local dealer for a full list of the PC Control Codes if needed.

Communication Protocol

Baud rate ........................................ 38400 bps
Data length ..................................... 8 bits
Parity .............................................. No parity
Stop bit .......................................... One bit
X on/off .......................................... None
Communications procedure ........... Full duplex