Interrupt selection, Table d-3. example switch settings with correspond, Table d-3 – National Instruments PC-DIO-24/PnP User Manual

Page 88

Advertising
background image

Appendix D

Using Your PC-DIO-24 (Non-PnP) Board

© National Instruments Corporation

D-5

PC-DIO-24/PnP User Manual

Interrupt Selection

There are two sets of jumpers for interrupt selection on the PC-DIO-24
board. W3 is used for selecting the interrupt enable line. W2 is for
selecting the interrupt level. The location of these jumpers is shown in
Figure D-1.

Table D-3. Example Switch Settings with Corresponding Base I/O Address and I/O Address Space

Switch Setting

Base I/O

Address (hex)

I/O Address

Space Used (hex)

A9 A8 A7 A6 A5 A4 A3 A2

0

1

0

0

0

0

0

0

100

100–103

0

1

0

0

1

0

0

0

120

120–123

0

1

0

1

0

0

0

0

140

140–143

0

1

0

1

1

0

0

0

160

160–163

0

1

1

0

0

0

0

0

180

180–183

0

1

1

0

1

0

0

0

1A0

1A0–1A3

0

1

1

1

0

0

0

0

1C0

1C0–1C3

0

1

1

1

1

0

0

0

1E0

1E0–1E3

1

0

0

0

0

0

0

0

200

200–203

1

0

0

0

1

0

0

0

220

220–223

1

0

0

1

0

0

0

0

240

240–243

1

0

0

1

1

0

0

0

260

260–263

1

0

1

0

0

0

0

0

280

280–283

1

0

1

0

1

0

0

0

2A0

2A0–2A3

1

0

1

1

0

0

0

0

2C0

2C0–2C3

1

0

1

1

1

0

0

0

2E0

2E0–2E3

1

1

0

0

0

0

0

0

300

300–303

Note: Base I/O address values 000 through 0FF hex are reserved for system use. Base I/O address values
100 through 3FF hex are available on the I/O channel.

Advertising