Connecting the cables to the media gateways – Nortel Networks 1000E User Manual

Page 356

Advertising
background image

Page 356 of 466

Installing the Main Distribution Frame

NN43041-310

Standard 01.11

October 2008

Connecting the cables to the Media Gateways

Each Media Gateway and each Media Gateway Expander requires up to four
25-pair cables. The CS 1000E requires an additional terminal block at the
cross-connect terminal to terminate the 9-pin conductor auxiliary cable for
the

QUA6 Power Fail Transfer Unit (PFTU)

.

Procedure 82
Connecting the cables to the Media Gateways

1

Loosen the velcro straps at each connector you plan to use.

2

Connect a 25-pair cable to each of the connectors that contains a line or
trunk card. Refer to the card slot assignment plan.

3

Tag both ends of each cable with the equipment and connector numbers.
See Figure 153 on

page 357

and Figure 154 on

page 357

.

DANGER

Always use caution when installing or modifying
telephone lines. Do not install telephone wiring during a
lightning storm. Never touch uninsulated telephone
wiring unless the line is disconnected at the network
interface.

WARNING

Do not use the NE-A25B cable with the NTRB21,
NTAK10, NTBK50, or NTAK79 circuit cards.