Appendix C

Error Codes and Solutions

NI-488.2 User Manual

C-2

ni.com

EDVR (0)

EDVR is returned when the interface or device name passed to

ibfind

,

or the interface index passed to

ibdev

, cannot be accessed. The global

variable

ibcntl

contains an error code. This error occurs when you try

to access an interface or device that is not installed or configured properly.

EDVR is also returned if there is an internal driver error.

Solutions

Possible solutions for this error are as follows:

Use

ibdev

to open a device without specifying its symbolic name.

Use only device or interface names that are configured in the GPIB
Configuration utility as parameters to the

ibfind

function.

Use the NI-488.2 Troubleshooting Utility to ensure that each interface
you want to access is working properly, as follows:

Windows

1.

Select Start»Programs»National Instruments»
Measurement & Automation
.

2.

Select Help»Troubleshooting»NI-488.2 Troubleshooting Utility.

Mac OS X

Run Applications»National Instruments»NI-488.2»Troubleshoot.

EHDL

23

Input handle is invalid

EWIP

26

Wait in progress on specified input handle

ERST

27

The event notification was cancelled due
to a reset of the interface

EPWR

28

The interface lost power

Table C-1. GPIB Error Codes (Continued)