Troubleshooting guide, Read before calling service center, Trouble – NuTone CV350 User Manual

Page 6: Possible cause, Possible remedy

Advertising
background image

6

7

TROUBLESHOOTING GUIDE

NuTone

Trouble

1. Loss or decrease of

vacuum occurs.

2. Power unit does

not start.

3. Power unit fails to

stop when the hose
is removed.

NUTONE MODEL CV-352 SHOWN.

YOUR ACTUAL UNIT MAY VARY IN APPEARANCE.

Inlet
switch

Exhaust

guard

Mounting

bracket

Exhaust and

exhaust

coupling

Intake and

intake

coupling

Polarized

3-pronged

plug

Gasket

Canister
latch

6-gallon

disposable

soil bag

Secondary

safety filter

Bag

adapter

Inlet

Read Before Calling Service Center

Possible Cause

1a. Disposable bag filled.

1b. Obstruction in the hose. A blockage

in the hose can be determined by
inserting the hose into any Wall Inlet
and, while Power Unit is running,
check each additional inlet for
normal suction by holding the palm
of your hand over the open inlet. If
normal suction is felt at all other
inlets, insert the hose into a second
inlet. If the blockage still exists it is
located in the hose. However, if the
blockage does not occur when the
hose is changed, the blockage is
probably located in the tubing
system leading to the original inlet.

1c. Obstruction in the tubing system

inside the walls.

1d. Wall Inlet cover not properly sealed.

2a. Defective inlet.

Check other Wall Inlets.

2b. Thermoprotector has been activated.

2c. Blown fuse or tripped circuit breaker.

3a. An electrical short has occurred

somewhere in the system.

Possible Remedy

1a. Remove disposable bag and install

replacement.

Note:

Check secondary filter for possible dirt and

dust accumulation and wash to clean if necessary.

1b. Disconnect the hose from the wall Inlet and

insert a blunt instrument into the hose – slightly
smaller in diameter – such as a flexible garden
hose. Push the garden hose through the
cleaning system hose until the obstruction has
been cleared.

2b. Check the overload protector button located on

the front of the Power Unit.
(Push to reset system.

1c. Insert hose end into any inlet with Power Unit

running, place the palm of your hand over the
opposite end of the hose. When you can feel the
suction increase, hold your hand over the hose
end for a few seconds and then quickly remove
your hand. This procedure repeated several time
should clear the obstruction. If the blockage is
not cleared, service will be necessary.

3a. A complete check of all Wall Inlet and Power

Unit low voltage control lead connections
(external yellow leads). Turn system off by
removing fuse or tripping circuit breaker at
house fuse box.

1d. Check all Wall Inlet covers to be sure they are

closed and sealed tightly.

2a. Replace defective Wall Inlet.

2c. Replace fuse or reset circuit breaker.