HEATER PLACEMENT

PLANNING YOUR INSTALLATION

Have an authorized dealer install the heater. If you install the heater yourself, have your dealer review your installation
plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the requirements listed in
this manual.
For built-in enclosures, when determining the location of the heater, locate the wall studs (for horizontal penetrations). You
may wish to adjust the heater position slightly to ensure the vent does not intersect with a framing member.
Heater must be positioned so that no combustibles are within, or can swing within (e.g. drapes, doors), 48" of the front of
the heater.
If the heater is placed in a location where the ceiling height is less than 7' above the base of the heater, the installation
must follow the requirements in the section "Alcove Installations Requirements"

Read this entire manual before you install and use this heater. failure to follow the instructions may result in

property damage, bodily injury, or even death.

Check with local building offi cials for any permits required for installation of this pellet heater and notify your insurance
company before proceeding with installation.

Before installing we recommend placing the heater outside and load 5 pounds of pellets inside the hopper. Plug the heater
in and let it run on HIGH until the pellets run out. This will cure the paint and burn off the oils on the steel, there by mini-
mizing any smell inside the home.

Electrical Rating

115 Volts, 3.6 Amps, 60Hz

Watts During Start-Up Sequence

400 (approximately)

Watts During Operation

180 (approximately)

NPS40 Width

22 3/8"

NPS40 Height

30 1/2"

NPS40 Depth

26 5/8"

Weight

210 Pounds

Exhaust Collar

3"

Intake Collar

2"

NPS40 Hopper Cap.

55 Pounds

NPI40 Hopper Cap.

45 Pounds

EPA

Exempt

Burn Rate**

1.0 to 5.0 (Pounds Per Hour)

BTU/h**

8500 to 42500

Minimum Fireplace Opening Size

Front: 22 1/2* W x 20 5/8 H x 14 1/4 D
Back: 20 3/8 W

This heater is EPA exempt from Phase II requirements, but
has been tested for emissions using EPA test methods by
Warnock Hersey.

SPECIFICATIONS

EPA COMPLIANCE

* In order to install fl ashing fl ush to fi nished wall and centered within the opening the front opening of the fi replace or
enclosure must be 32 5/8" wide.

!