WIRING CONNECTIONS

All wiring must comply with local codes and unit must
be properly grounded.
1. While making wiring connections, support the heater

assembly on the bottom of the rough-in frame.

2. For 120 Volt operation, make wiring connections as shown

in Figure 4.

3. For 240 Volt operation, make wiring connections as shown

in Figure 5.

4. Use wire nuts to make connections. Insulate all

connections with electrical tape.

SECURING THE HEATER

1. Dress all wiring back to into junction box.
2. Locate center holes in housing flange and align with

mounting holes in grille.

3. Use two provided screws to attach grille to housing.

OPERATION

Turn thermostat fully clockwise to HIGH position. Allow

heater to run until room is at desired temperature. Adjust
thermostat as required to maintain desired temperature. Turn
the thermostat to FULL COUNTERCLOCKWISE position when operation is no longer desired.

Thermal protector: If for any reason temperatures increase beyond normal limits, a safety thermal fuse will shut heater off. The

heater will require servicing by a qualified electrician.

Check entire installation to determine cause of overheating.

4

1

2

3

4

1

2

3

FIGURE 4

FIGURE 5

120vAC

240vAC

GREEN OR BARE

GROUND

GREEN
GROUND

WHITE

BLACK

BLACK

RED

WHITE

YELLOW

120vAC

60HZ

GREEN OR BARE

GROUND

GREEN
GROUND

RED OR WHITE

BLACK

BLACK

RED

WHITE

YELLOW

240vAC

60HZ

NO
CONNECTION

NO
CONNECTION

Product specifications subject to change without notice.