NTI RACKMUX RACKMOUNT ANSI TERMINAL DRAWER

4

1. INSTALLATION

1.1 Rack Mounting Instructions

1.1.1 Standard Rack

The RACKMUX was designed to be mounted to a rack and includes mounting flanges to make attachment easy.

1. Determine the mounting height in the rack for the drawer. It should be a height comfortable to use the keyboard and see the
LCD display. Mark holes in each of the 4 corner cabinet rails at points all level with each other.

2. Secure the rear brackets to the rear rack cabinet rails at the holes marked in step 1 using #10-32x3/4” screws and cage nuts
(supplied). Be sure to tighten the screws securely.

3. Lift the keyboard into position and line the studs on the left and right sides up with the slotted openings in the rear bracket.
Apply the nuts (supplied) to the studs but do not tighten the nuts yet.

FYI: There are 5 mounting studs provided on each side of the RACKMUX. Depending on the depth of the rack and
distance apart of the cabinet rails, the position of the rear bracket may make all 5 studs available for use. In this case,
apply the 2 nuts to the studs furthest apart from each other on each side.

4. Slide the drawer in until the top holes in the front bracket flanges line up with the holes marked in step 1. Secure the front
brackets on the drawer to the front cabinet rails using #10-32x3/4” screws and cage nuts (supplied). Be sure to tighten the
screws securely. Then tighten the nuts applied in step 3.












Figure 1- Mount RACKMUX to rack

Note: To provide sufficient room for the LCD monitor to be opened to a proper viewing angle (a minimum 90 degree
position from the keyboard), ensure that all devices mounted above the RACKMUX extend no more than 1.75” from the
rack frame. (See Fig. 2)


















Figure 2- Position RACKMUX with clearance to open




Apply nuts (supplied) to studs and
secure rear brackets to drawer.

Front bracket
flange on drawer

Rear bracket
flange

Drawer

Front Cabinet
Rail

Rear Cabinet
Rail

Rear bracket overlapping
drawer

(Rear edge
of drawer)

Stud on drawer

Side View of RACKMUX-T15

"X" must be
less than 1.75"
for LCD to open
to full 90

X

90

Server mounted
above RACKMUX
in the same rack