Erase display, Set diagnostic state on – NCR Customer Display NCR 5972 User Manual

Page 35

Advertising
background image

Chapter 4: Programming Set Up

4-5

Erase Display

Format: 

1B 02

 

Description:  This command clears all of the displayed characters 
by writing a space to each display position. A space is defined as 
character 0x20 of the current character set. The cursor moves to the 
0 position. 

Set Diagnostic State On

Format: 

1B 04

 

Description:  This state is exclusive from the On and Low Power 
States. This command causes the firmware to display the current 
firmware part number of the device for five seconds, and then step 
through each installed 256‐character set (default and user‐defined) 
displaying one character at a time on all 40 display positions at a 
rate of about one character per second. The firmware starts with the 
currently selected character set, and then displays all of the 
characters from the other sets the same way. This continues until 
one of the other state commands is performed. Prior display data is 
saved and can be restored before sending the Set Display State On. 

Note:

The LCD only has one character set. 