English – NEC MultiSync S521 User Manual

Page 31

Advertising
background image

English-29

English

This LCD monitor can be controlled by connecting a personal computer with a RS-232C terminal.

NOTE: When you use this function, EXTERNAL CONTROL should be “RS-232C” (See page 23).

Functions that can be controlled by a personal computer are:

Power ON or OFF

Switching between input signals

Connection

LCD Monitor + PC

NOTE: If your PC is equipped only with a 25-pin serial port connector, a 25-pin serial port adapter is required. Contact your

dealer for details.

* In order to function, the RS-232C OUT terminal can only be connected to another monitor of the same model.

Do not connect to other types of equipment.

To control monitor or multiple monitors that are daisy-chained together please use the control command. Instructions for the
control command can be found on the CD included with the display. The file is called “External_control.pdf”.

Multiple monitors that are daisy-chained have a limit to the conectable monitor.

1) Interface

This LCD monitor uses RXD, TXD and GND lines for RS-232C control.
The reverse type cable (null modem cable) (not include) should be used for RS-232C control.

2) Control command diagram

Please see file “External_Control.pdf” on the CD-ROM.

PROTOCOL

RS-232C

BAUD RATE

9600 [bps]

DATA LENGTH

8 [bits]

PARITY BIT

NONE

STOP BIT

1 [bit]

FLOW CONTROL

NONE

RS-232C Cable

PC

(Out)

RS-232C Cable

RS-232C (OUT)

MultiSync

RS-232C (IN)

RS-232C (OUT)

RS-232C (IN)

IN

OUT

MultiSync

Controlling the LCD monitor via RS-232C Remote Control

MultiSync